video

Power Module Heat Sink

A power module heat sink is the aluminum cooler that a high-power semiconductor module bolts onto — IGBT, MOSFET / SiC, rectifier bridge, thyristor (SCR), or IPM. Its job is simple to state and hard to do cheaply: pull the switching and conduction losses out of a small module footprint fast enough that the junction stays inside its rated temperature. We build these power module heat sinks with a flat, high-precision base that seats the module square, and fins tuned to your airflow and module layout.

  • Product Introduction

A power module heat sink is the aluminum cooler that a high-power semiconductor module bolts onto - IGBT, MOSFET / SiC, rectifier bridge, thyristor (SCR), or IPM. Its job is simple to state and hard to do cheaply: pull the switching and conduction losses out of a small module footprint fast enough that the junction stays inside its rated temperature. We build these power module heat sinks with a flat, high-precision base that seats the module square, and fins tuned to your airflow and module layout.

 

Power Module Heat Sink 4

 

- Flat, high-precision base - seats IGBT / MOSFET / SiC modules with no shimming; ≤0.10 mm flatness (≤0.05 mm skived)

- Module-footprint ready - 62 / 94 / 106 / 140 mm, and your custom pad; drilled, tapped, or pocketed

- Fin tuned to your cooling - forced-air, natural convection, or ultra-dense skived for the highest flux densities

- Made to your layout - custom length, fin height, hole pattern, anodizing; extruded or skived route

 

Request A Quote

 

 

What a Power Module Heat Sink Does

 

A power module heat sink is, in mechanical terms, an aluminum block with a thick bottom plate and a row of fins - but the part that matters to a buyer is how it is engineered around the module. A power semiconductor (IGBT, MOSFET, SiC, rectifier, thyristor) converts and switches large currents; every switching and conduction loss that is not conducted away becomes junction heat. The cooler's flat base spreads that heat into the fins, and the fins hand it to the air. The lower the total thermal resistance from junction to air, the more current your module can carry at a given ambient temperature.


For an overseas buyer, the practical value is this: a well-matched power module heat sink lets your inverter, rectifier, or power supply hold rated output on a hot factory floor instead of derating or failing. Because modules differ in footprint, loss, and cooling, the cooler is sized per module - not pulled from a generic catalog.


Engineering note for buyers:

Send the module part number (footprint and Rθjc), total losses (W), ambient temperature, mounting height, and whether cooling is forced-air or natural. We match fin height, pitch, base thickness, and process (extruded vs skived), then return a module-case-temperature estimate and margin before tooling.

 

Product Overviews

 

Three angles of the same cooler - the raw extruded profile, the finished base with a power module mounted, and a cross-section of the fin-to-base thermal path.

 

Power Module Heat Sink 2
01.

Raw extruded profile

Thick flat base with parallel fins. The starting shape before holes and anodizing.

02.

Finished, module mounted

Thick base drilled/tapped; module seats square. Fin pitch tuned to your airflow.

Power Module Heat Sink 1
 
Power Module Heat Sink 3
03.

Cross-section

Thick base = low interface resistance, even spread. Fins sized to your cooling.

 

 

 

 

Why Module Builders Specify Our Power Module Heat Sink

 

 

 

 

One Base Family, Many Modules

A single flat-base profile family scales across IGBT, MOSFET/SiC, and rectifier modules by changing length and hole pattern - fewer line items, simpler reordering, stable lead time.

For Procurement Teams

 

 

Sized to Your Loss & Airflow

We tune fin height and pitch to your measured losses and airflow, and return a module-case-temperature estimate so you confirm margin against the Tj limit before sign-off.

For Power Electronics Engineers

 

 

Module Seats Square

High-precision base (≤0.10 mm flatness) means the IGBT module bolts down with no shimming and the thermal interface sheet compresses evenly - lower junction temperature, fewer field returns.

For VFD OEMS

 

 

Stock & Private Label

Common module-base profiles kept in stock, neutral or branded, with tiered pricing for recurring power-module cooler programs across inverter and power-supply customers.

For Distributors

 

Technical Specifications

 

Reference build for power semiconductor modules. Dimensions and mounting are set to your module and enclosure.

 

Parameter Specification
Base Material Aluminum 6063-T5 ; optional 6061-T6; copper-insert on request
Profile Type Extruded, parallel-fin; skived-fin for high fluxdesity; optinoal angled fin
Module Footprint Support 62 / 94 / 106 / 140 mm standard; custom pads and multi-module layouts
Base Thickness 8–25 mm; thicker for high-current spreaders
Fin Height 20-100 mm typical; matched to available height and airflow
Fin Pitch 3-10 mm; wider pitch for dusty environments, tighter for forced air
Base Flatness  ≤ 0.10 mm extruded; ≤0.05 mm skived
Mounting Through-holes, M3-M8 tapped, pockets; insulator-ready
Surface Finish Natural; clear or black anodizing
Thermal Resistance ~0.15–2.0 °C/W depending on process, size, and airflow
Cooling Method Forced convection, natural convection, or hybrid
Certifications RoHS, REACH compliant; ISO9001 manufacturing

 

Power Module Heatsink Selection Guide

 

Match the cooler to your module type, losses, and cooling method.

 

Module/Application Typical Loss Recommended Build
IGBT module (inverter, VFD, PCS) 50-600W Extruded flat-base, forced-air fins, 62-140 mm footprint
MOSFET/SiC module 30-300W Skived or dense extruded fin, Rθ, flat base for SiC
Rectifier bridge / diode module 20-200W Compact extruded, natural or low-airflow convection
Thyristor / SCR module 50-400W Thick base spreader, drilled for stud/tab mount
IPM (intelligent power module) 20-150W Low-profile extruded, pre-drilled to module pattern
Sealed / passive enclosure Any Natural-convection tall fin, wider pitch, black anodize

 

 

Technical Differences: Which Cooling Approach Fits Your Module

 

A power module heat sink is one option in a spectrum of cooling methods. Picking the wrong one either wastes budget (oversized liquid plate) or risks failure (undersized fin). Here is how the common approaches compare for power-semiconductor modules.

 

Approach Best For Limit Relative Cost
Extruded fin heat sink (forced air) Most IGBT / MOSFET / IPM modules in fan-cooled cabinets Needs airflow; limited flux density Low
Skived fin heat sink Highest flux density, SiC, tight space, low Rθ Higher cost; thinner fins are delicate Medium-High
Angled/skew fin Forced-air flow that benefits from guided convection Niche; tooling-specific Medium
Heat-pipe/vapor chamber Spreading heat away from a hot spot to a remote fin stack Working fluid, orientation-sensitive High
Liquid cold plate Very high power density, sealed enclosures Pump, fluid,leak risk, cost High

 

Rule of thumb: If your module runs under a few hundred watts in a fan-cooled or naturally-vented enclosure, an extruded or skived power module heat sink is almost always the right answer. Move to heat-pipe or liquid cooling only when flux density or a sealed cabinet makes fins impractical.

 

Material Comparison: Aluminum vs Copper vs Hybrid

 

The base material trades cost against thermal performance. For most power module heat sinks, aluminum wins on price and weight; copper wins on conductivity but is rarely worth it except at the interface. We also offer copper-insert bases for a targeted boost.

 

Material Thermal Conductivity Density Cost When to Use
Aluminum 6063-T5 ~209 W/m·K 2.70 g/cm³ Low Default for extruded and skived module coolers
Aluminum 6061-T6 ~671 W/m·K 2.70 g/cm³ Low-Med When higher stiffness/strength is needed
Copper (C1100) ~398 W/m·K 8.96 g/cm³ High Interface plates, high-flux inserts only
Copper-insert base Aluminum body + copper core Medium Medium Lower Rθ at the module without a full copper part

Recommendation: Choose 6063-T5 extruded or skived for the bulk of your program. Use a copper-insert base only at the hottest power stage (e.g., a SiC phase leg) where a few °C of case-temperature reduction protects the junction - this is the cost-effective middle ground our engineers usually propose.

 

 

Manufacturing Process

 

From extruded bar to a finished, drive-ready cooler.

 

Extruded

6063 bar, dense fins

Cut to Length

Sawn to module spec

CNC Drill/Tap

Module holes, threads

Anodize (opt.)

Natural or black

Deburr & Clean

Assembly-ready

Inspect

Flatness, holes, finish

 

 

 

 

production process

 

Application Scenarios

 

Inverters & Converters

IGBT-based solar, energy-storage, and frequency inverters (PCS, VFD, AC drive).

Rectifiers & Power Supplies

Diode / thyristor rectifier bridges, SMPS, and industrial power modules.

SiC / MOSFET Stages

High-frequency, high-flux-density wide-bandgap modules needing low Rθ.

Motor Drives

VFD, servo, and soft-starter power modules in automation.

EV & Charging

On-board chargers, DC/DC, and traction inverter modules.

UPS & Grid Equipment

Uninterruptible power and STATCOM / SVG power units.

 

heat sink application

 

Quality Inspection (Testing & QC)

 

Every power module heat sink ships against an inspection plan tied to your module's seating and thermal requirements. Our QC covers the points that actually affect junction temperature and field returns.

 

Inspection Point Method Acceptance
Incoming material Mill cert + spectrometer spot check 6063/6061 per order; no off-grade alloy
Base flatness Surface plate / CMM or straightedge  ≤ 0.10 mm extruded; ≤ 0.05 mm skived
Hole position & size CMM / pin gauge Per drawing, ±0.05 mm; thread go/no-go
Anodizing thickness Eddy-current coating gauge 8–15 µm typical; logged per batch
Thermal resistance (sample) Bench test vs module simulation Within quoted Rθ margin (report attached)
Visual & burr 100% visual, deburr check No sharp edge, no finish defect
CoC / traceability Batch record Material cert, inspection report, RoHS/REACH

For buyers: Ask for the batch inspection report and material certificate with your first order - we issue a Certificate of Conformity (CoC) and can supply PPAP-level documentation for automotive or grid programs on request.

 

Cost Factors

 

Understanding what drives price helps you specify a cooler that meets the thermal budget without paying for capability you do not need. The main levers on a power module heat sink:

Factor Effect on Cost Buyer Tip
Process route Extruded<skived<copper-insert Use extruded unless flux density forces skived
Size & fin height More aluminum = higher unit cost Size to real losses, not worst-case ambient
CNC machining Holes, pockets, threads add setup Reuse a standard module footprint where possible
Anodizing Black anodize adds a step  Natural finish is fine unless emissivity/look matters
Tooling/NRE One-time for new extrusion die or skive Amortize across volume; ask about shared dies
Order quantity Volume pricing at 1,000+ Pototype MOQ is low; lock volume price early
Logistics FOB vs DDP; carton vs crate DDP simplifies import; cosolidated shipments save freight

Budget guidance: For a typical forced-air IGBT module cooler, the extruded route with standard machining is the lowest landed cost. Move to skived only for the hottest stage, and specify natural (not black) anodizing unless emissivity is a real factor - that keeps cost down while protecting the junction.

 

Customization Process

 

From your module drawing to a finished, module-ready cooler. A typical custom power module heat sink program runs in seven steps.

 

01.

RFQ

Module P/N, losses, airflow, height, finish

02.

DFM Review

We check footprint, holes, flatness feasibility

03.

Quote & Thermal Est.

Profile, RΦ, case-temp margin, price

04.

Sample

CNC-modified or new-die sample, 5-10 days

05.

Mass Production

Extruded / skive, machine, finish, inspect

06.

QC&Docs

Report, CoC, material cert, RoHS/REACH

07.

Ship

FOB/CIF/DDP to your port or door

 

For modified standard profiles we skip the new-die step, so samples can ship in 5–7 working days. Full custom extrusions or skived parts add tooling lead time, which we confirm in the quote.

 

1Custom Heatsinks Design

 

What Customers Say

 

 

What Customers Say

"We standardize their power module heat sink across IGBT and SiC phases of a 150 kW PCS. The same flat-base profile family took three module footprints just by changing length and hole pattern. First-article flatness came in under 0.08 mm, no shimming needed."
product-60-60

T. Berger

Power Electronics Lead, Germany

"Their material comparison table settled a cost-versus-case-temperature argument on our design team. We stayed with extruded 6063 for the volume inverter and moved only the highest-density SiC stage to a skived fin. Thermal estimate matched our bench within 2 °C."
product-60-60

A. Costa

Hardware Engineer, Brazil

"For a rectifier bridge and an IGBT in the same cabinet they gave us one shared-base layout instead of two separate coolers. Fewer parts, simpler assembly, and the inspection report with every batch keeps our QA happy."

 

product-60-60

S. Nakamura

Procurement, Japan

 

zp global customers

 

FAQ

 

Q: What is a power module heat sink used for?

A power module heat sink mounts high-power semiconductor modules - IGBT, MOSFET / SiC, rectifier bridge, thyristor (SCR), and IPM. These modules switch and conduct large currents; the cooler carries the resulting losses out of the enclosure so the junction stays within its rated temperature. It is the part that decides whether your inverter, rectifier, or power supply holds rated output or derates.

 

Q: Extruded, skived, or copper - which should I choose?

For most modules, an extruded aluminum flat-base cooler is the lowest-cost answer and covers IGBT, MOSFET, rectifier, and IPM needs. Choose skived fins when flux density is high or space is tight (common with SiC). Use copper-insert only at the hottest stage. See our technical-difference and material-comparison sections above for the full trade-off.

 

Q: How do you size the heatsink to my module?

Send the module part number (footprint and Rθjc), total losses in watts, ambient temperature, available mounting height, and whether cooling is forced-air or natural. We match fin height, pitch, base thickness, and process, then return a module-case-temperature estimate and margin before tooling.

 

Q: Can the base be machined for my module footprint?

Yes. The flat base is drilled, tapped, or pocketed to seat 62 / 94 / 106 / 140 mm standard modules (or your custom pad) with ≤0.10 mm flatness (≤0.05 mm skived), so the module bolts down square with no shimming.

 

Q: What quality documents do you provide?

Every batch ships with a material certificate, inspection report (flatness, hole position, anodizing thickness, sample Rθ), and RoHS/REACH statement. We also issue a Certificate of Conformity, and can supply PPAP-level documentation for automotive or grid programs on request.

 

Q: What is the MOQ and lead time?

Modified-profile samples ship in 5–7 working days with a low prototype MOQ. New extrusions or skived parts add tooling lead time, confirmed in the quote. Volume repeats run on a scheduled basis with tiered pricing for 1,000+ programs.

 

Q: Do you support SiC and high-flux-density modules?

Yes. SiC modules run hotter and need lower case-to-air resistance; we recommend a skived or dense-fin build with a flat, high-precision base, and can add a copper-insert stage where a few °C of case-temperature reduction protects the junction.

 

Related Heat Sink Pages

 

- IGBT Module Heat Sink - power module cooling, generic
- Solar Inverter Heat Sink - PV / grid-tie inverter cooling
- Skived Fin Heat Sink - one-piece high-power cooler
- Custom Extruded Aluminum Heat Sink - hub for made-to-spec profiles
 -CNC Machined Aluminum Heat Sink - to-drawing machining

 

 

Hot Tags: power module heat sink, China, suppliers, manufacturers, factory, customized, wholesale, buy, price, free sample, Custom Heat Sinks

Send Inquiry

(0/10)

clearall